What the catalogue shows
The HA-01 reference gives a nominal 3 × 5.95 × 2.8 m sequence (approximately 118.1 × 234.3 × 110.2 in, same order) and shows separate structural and enclosure components. Confirm the dimension order and layout.
HA-01 · hand-assembled reference
Compare detachable container houses as a component-based building kit for offices and accommodation. Review the frame, panels, connections, packing and local assembly cost together.
HA-01 · HAND-ASSEMBLED REFERENCE
A component-based module can make the supply scope easy to inspect. The buying decision depends on the member schedule, fixing package and who carries out assembly.
The HA-01 reference gives a nominal 3 × 5.95 × 2.8 m sequence (approximately 118.1 × 234.3 × 110.2 in, same order) and shows separate structural and enclosure components. Confirm the dimension order and layout.
The illustration labels panels, a steel door and uPVC window. It does not establish a finished interior or installed MEP package at dispatch.
Agree local crew, tools, component inventory, frame assembly, seals, anchorage and service connections before the kit is ordered.
PRODUCT-SPECIFIC BUYING POINTS
A meaningful comparison starts with the selected HA-01 schedule and a current drawing, not a general photo of a container house.
The illustrated schedule labels a 16 mm MgO floorboard; the English schedule states 18 mm. Confirm the current model BOM and drawing before quoting the floor thickness.
A SOURCE DETAIL TO RESOLVE
Both labels appear in the source. Ask for the current HA-01 drawing and BOM before pricing a final board.
CONFIGURE THE SUPPLY SCOPE
Select the items to discuss. Availability and whether each item is installed, packed loose or excluded must be agreed.
Select any requests that matter to your project.
YOUR PROJECT BRIEF
Include destination, quantity and the local assembly team so we can review a complete kit scope.
Review the brief before exporting. No enquiry is sent automatically.
Options are project requests. Confirm availability, fitted / loose items, exclusions, site work and price in the current drawing, BOM and quotation.
EXPLORE IN 3D · PLAN YOUR CONFIGURATION
Turn the building. Look inside. Compare a finish and layout, then bring your choices into the project brief.
YOUR PLANNING CONCEPT
Detachable · Project office · Mineral white · 1 module
Illustrative planning model. Layouts, openings, furniture, deployment and finishes are concepts. Confirm dimensions, movement details and supplied scope against the selected model drawings.
VISIBLE DETAIL · MODEL DATA · PROJECT SCOPE
Choose a part of the building. The reference image identifies what is shown; the adjacent schedule identifies the model information and what the project drawing must resolve.
The illustrated schedule labels a 16 mm MgO floorboard; the English schedule states 18 mm. Confirm the current model BOM and drawing before quoting the floor thickness.
HA-01 · hand-assembled reference
Source nominal sequence. Confirm dimension order, external size and clear internal geometry.
Set partitions, circulation and module-to-module interfaces on a general arrangement.
The assembled module dimensions do not define each packed component or transport bundle.
FROM ORDER TO SITE
Identified structural members, panels, openings and the agreed fittings / services.
Define fit-up, fixings, sealants, testing, local licences and who accepts each stage.
Compare the kit price, freight, site labour, equipment and local completion on the same scope.
QUESTIONS BUYERS ASK
Review the decisions that matter for this stage of your project.
A detachable kit is assembled from identified frame members and enclosure components at the destination. Ask for the current component schedule, assembly sequence and packing list for the exact model.
The HA-01 reference names a carriage bolt, but that alone is not a complete fixing specification. Request the bolt size, grade, washers, nuts, quantities, corrosion protection and joint drawings for the selected kit.
The HA-01 source shows 50 mm and 75 mm rock-wool wall-panel labels. Its illustration labels a 16 mm MgO floor board, while the English schedule states 18 mm. Confirm the actual board type and thickness in the current bill of materials before ordering.
The reference illustration identifies a steel door and a window, while finish and glazing alternatives are presented as options. Confirm quantities, sizes and whether each item is installed, packed loose or excluded.
Discuss the intended relocation frequency with the supplier. Connections, panels, seals, fixings and any services should be inspected after dismantling; replacement parts and the handling method depend on the selected design.
Overseas installation personnel can be discussed according to project quantity, location and scope. Travel, accommodation, local labour, equipment and personnel costs should be allocated and itemised where applicable.
An assembly format does not remove the need to plan supports, anchorage, temporary stability, lifting, service connections and local permissions.
A MORE USEFUL FIRST QUOTATION
A focused brief helps compare the selected building, evidence, freight and local completion on the same basis.
Prepare a detachable enquiryThe enquiry flow prepares a brief for review and export. No enquiry is sent automatically.