PROJECT MANAGEMENT · MEETINGS · SITE SUPPORT

Modular site offices and container office buildings.

Plan modular site offices, portable cabins and container office layouts around team size, meetings and services. Define the selected building package and the work completed locally.

Plan your site-office package
  • Workspace planned around headcount
  • Shell, finishes and services separated
  • Local installation interfaces defined
Product photographyPhotograph: a two-level glazed modular office with external stairs.

WORKPLACE BRIEF

Plan the office before choosing the box.

Start with the people, meeting spaces and service points. The right package depends on the work your team must do on day one.

Product photographyGlazed modular office reference; the internal arrangement and included services are not visible.

ARRIVAL CONDITION & RESPONSIBILITY

What arrives as an office?

Set the factory and site boundary before comparing quotations. Actual inclusion and completion level depend on the selected model and written offer.

  1. 01

    Building package

    Confirm the selected shell, partitions, doors, windows and floor / ceiling finishes in the written scope.

  2. 02

    Workplace fit-out

    Ask whether light fittings, sockets, cooling, desks and data provisions are installed, supplied loose or excluded.

  3. 03

    Local completion

    Plan foundations and anchorage, incoming power, internet provider, local connections and commissioning.

SYSTEM COMPARISON

Choose by team size and site work

Flat-pack

Discuss for repeatable rooms and a site crew able to assemble the selected package.

Detachable

Discuss when the local team wants to review individual components and assembly scope.

EXPLORE IN 3D · PLAN YOUR CONFIGURATION

Get a feel for the space.

Turn the building. Look inside. Compare a finish and layout, then bring your choices into the project brief.

Interactive architectural planning model.
Flat-packProject office · Exterior view
Preparing your 3D view…
100%

Drag to rotate · Ctrl / ⌘ + scroll to zoomTap Interact, then drag or pinch.

YOUR PLANNING CONCEPT

Exterior finish
Site arrangement

Separate modules shown as a site-layout concept.

Current selection

Flat-pack · Project office · Mineral white · 1 module

Use this in my enquiry

Illustrative planning model. Layouts, openings, furniture, deployment and finishes are concepts. Confirm dimensions, movement details and supplied scope against the selected model drawings.

APPLICATION REFERENCES

Explore workspace arrangements.

Explore the configurations and visible details. The selected drawing and quotation define the actual package and its delivery condition.

AI-cleaned source referenceGlazed-front white module shown as a complete exterior.
01

Single project office

A starting point for a local management office, reception or dedicated team room. Choose desk and storage positions before locating sockets, data points and cooling equipment.

  • Workstations and visitor access
  • Daylight, privacy and solar exposure
  • Power and data-entry locations
Product photographyPhotograph of joined white modules; the internal layout is not visible.
02

Linked management workspace

For a brief that combines work areas with a meeting room, drawing review or document storage. The connection opening, reinforcement and weather interface need to follow the selected system.

  • Room zoning and circulation
  • Module opening and connection detail
  • Meeting-room acoustic brief
Product photographyTwo-level office reference with glazing, balcony and stairs.
03

Project-office compound

For a larger site team or phased project. Plan the office footprint, access, external circulation and future relocation together. A stacked arrangement requires its own structural and local review.

  • Phased module quantities
  • Stairs, access and escape strategy
  • Support, anchorage and relocation plan

THE DETAILS BEHIND THE BRIEF

Coordinate openings, finishes and office services.

AI-cleaned source referenceThe entrance and glazed front are visible in this exterior reference image.
01

Openings that work for the desk plan

Place doors and windows against the furniture layout and circulation route. Review glare, shading, opening operation, safety glazing and the project’s thermal requirements.

Request: dimensioned general arrangement and door / window schedule.

AI-cleaned source referenceSPC interior floor-finish samples; these are material references, not an installed office floor.
02

Finishes chosen for daily use

Compare the finish appearance with cleaning, chair traffic, moisture exposure and replacement needs. Floor-board and support specifications belong to the selected module configuration.

Request: finish sample reference, floor build-up and maintenance instructions.

English-redrawn reference diagramExploded reference diagram of the hand-assembled system, showing its frame and enclosure parts.
English component key 18 callouts
  1. 0150 × 50 grooved roof purlin
  2. 0240 × 80 roof purlin
  3. 03Panel-retaining channel
  4. 0440 × 60 roof purlin
  5. 05Carriage bolts
  6. 0650 / 75 mm rock-wool sandwich panel
  7. 07Column — source designation 160 × 2.3
  8. 08Corner fittings — 8 pcs
  9. 09Grooved base-frame short beam — 160 × 2.3
  10. 1040 × 80 floor joist
  11. 11Roof sheet
  12. 12Glass-wool insulation
  13. 13Ceiling liner sheet
  14. 14Steel door
  15. 15Single-glazed uPVC sliding window
  16. 1616 mm MgO floorboard — source diagram label
  17. 17Grooved base-frame long beam — 160 × 2.3
  18. 1880 × 80 floor joist

The illustrated schedule labels a 16 mm MgO floorboard; the English schedule states 18 mm. Confirm the current model BOM and drawing before quoting the floor thickness.

03

A defined building and service interface

For this system, coordinate the frame, wall panels, floor board and roof layers with service penetrations. Use the relevant connection drawing for each selected model.

Request: model BOM, connection details and marked service-entry positions.

YOUR PROJECT REQUIREMENTS

Build an office enquiry

Choose the workplace details you want quoted. You can leave any item undecided.

Make the delivery condition explicit

Request a room-by-room quotation that says what is factory-installed, packed loose and left for the site team.

Useful documents to request

  • Dimensioned furniture and opening plan
  • Electrical / data point schedule and supply boundary
  • Floor, ceiling and partition finish schedule

YOUR DISCUSSION POINTS 0 selected

Power and IT provisions to discuss

Selections are discussion requests. Availability, price and what is included must be confirmed for the selected model.

Add these to my enquiryThe next page prepares a brief for review; it does not send an enquiry automatically.

FROM PROJECT BRIEF TO HANDOVER

Make the next decision clear.

01

Brief the workplace

Headcount, desks, meeting capacity, project duration and destination.

02

Define the layout

Room zoning, openings, access, services and selected building system.

03

Freeze the package

Drawing revision, BOM, finishes, packing and factory / site responsibilities.

04

Deliver and hand over

Agreed assembly checks, service commissioning and project acceptance records.

QUESTIONS BUYERS ASK

Frequently asked questions.

Review the decisions that matter for this stage of your project.

How many modules will my site office need?

Start with staff count, working areas, meeting rooms, reception, storage and circulation. A dimensioned layout and selected module size are needed before confirming the number of units.

Can several units be connected into an open-plan office?

A joined layout can be assessed. Ask for the clear internal space, structural openings, inter-module connection, weather sealing and local engineering to be reviewed on the proposed plan.

Are lighting, sockets, data points and air conditioning included?

These should be itemised. Specify the number and location of outlets, lights, data routes and cooling equipment; the quotation should state what is factory-installed, loose, locally supplied or excluded.

Can the office be relocated after a construction project?

Relocation depends on the system and design. Review lifting points, connections, foundations, service disconnection and any components or seals that need inspection or replacement.

Who connects power and internet at the site?

The supply boundary must be agreed in the quotation. Incoming power, utility connection, local licensed work and an internet service provider should be planned with the site team.

What should I provide to receive a useful office proposal?

Send the destination, team size, required rooms, sketch or available area, preferred delivery date and the site’s power, access and installation arrangements.

Can we add more rooms later?

Discuss the expansion sequence before the first order. Connection openings, structure, circulation and service capacity need to accommodate the intended phases.

A USEFUL FIRST ENQUIRY

Plan your site-office package.

Share the inputs below to focus the configuration and supply discussion. If the project is still at feasibility stage, describe the users, location and problem to solve.

Plan your site-office package

The enquiry page prepares a brief for review and export. It does not send to a sales inbox in this edition.

Include in your brief

  • Project country, state / province and city
  • Staff numbers, desks and meeting requirements
  • Single, linked or stacked layout preference
  • Site utility supply and local installer availability
  • Quantity, project duration and required delivery window
WhatsApp