English component key 18 callouts
- 0150 × 50 grooved roof purlin
- 0240 × 80 roof purlin
- 03Panel-retaining channel
- 0440 × 60 roof purlin
- 05Carriage bolts
- 0650 / 75 mm rock-wool sandwich panel
- 07Column — source designation 160 × 2.3
- 08Corner fittings — 8 pcs
- 09Grooved base-frame short beam — 160 × 2.3
- 1040 × 80 floor joist
- 11Roof sheet
- 12Glass-wool insulation
- 13Ceiling liner sheet
- 14Steel door
- 15Single-glazed uPVC sliding window
- 1616 mm MgO floorboard — source diagram label
- 17Grooved base-frame long beam — 160 × 2.3
- 1880 × 80 floor joist
The illustrated schedule labels a 16 mm MgO floorboard; the English schedule states 18 mm. Confirm the current model BOM and drawing before quoting the floor thickness.
Resolve conflicting labels on the current BOM.
The visible diagram labels a 16 mm MgO floor while the English schedule states 18 mm. A quotation should use the current model BOM and drawing revision, rather than silently selecting one value.
- Keep HA-01 separate from the FP-01 flat-pack specification.
- Confirm external and clear internal geometry on the current general arrangement.
- Resolve material, thickness and connection discrepancies before production.
Ask for: current general arrangement, BOM, revision history and a closed clarification list.